Nitrate Removal Systems
Nitrates level in drinking should be less than 50 mg/L as specified by the DWI. Nitrate removal systems usually only require pre-filtration and de-chlorination (if chlorine is present) as pre-treatment.
These two steps are necessary to protect the anion bed from oxidation and physical fouling.
Please refer to the tables below for both Simplex and Duplex System options, refer to Recommended Service Flow (m3/hr) to choose the right one for your flow rate. Please note depending on your delivery address there may be additional charges for delivery. Please contact us on 0330 113 7181 for more info or if you wish to order.
SIMPLEX NITRATE UNITS, 20 – 60 LITRES
Simplex Units with Clack® WS1 Valves, Time Clock (TC) and Metered (CI)
Resin Volume | 20 litres | 30 litres | 40 litres | 50 litres | 60 litres |
PART No | WF0835TC-N | WF1035TC-N | WF1044TC-N | WF1054TC-N | WF1252TC-N |
Time Clock Valve price ex VAT | Call for price | Call for price | Call for price | Call for price | Call for price |
PART No | WF0835CI-N | WF1035CI-N | WF1044CI-N | WF1054CI-N | WF1252CI-N |
Metered Valve price ex VAT | Call for price | Call for price | Call for price | Call for price | Call for price |
Tank Size (inches) | 8 x 35 | 10 x 35 | 10 x 44 | 10 x 54 | 12 x 52 |
Recommended Service Flow (m3/hr) | 0.8 | 1.2 | 1.6 | 2.0 | 2.4 |
Volume Capacity between Regens @ 75 ppm (m3) | 5.3 | 8.0 | 10.7 | 13.3 | 16.0 |
Brine Tank Volume (litres) | 85 | 85 | 85 | 95 | 95 |
Salt Usage per Regen (kgs) | 3.0 | 4.4 | 6.0 | 7.5 | 9.0 |
WS1 Injector Colour | White | Blue | Blue | Blue | Yellow |
WS1 Drain Line Flow Controller | 017 | 022 | 022 | 027 | 042 |
Approx Footprint DxWxH - cms | 38x66x109 | 38x66x109 | 38x66x132 | 40x68x157 | 42x70x152 |
Approx Regen Duration (minutes) | 70 | 75 | 80 | 80 | 80 |
NOTE:
Optional extras include – Clack® Valve Wrench [V3193], Clack® 1" Bypass Valve Assembly [V3006], Clack® ¾" Male BSP Adaptor Kit [V3007-14], Clack® No Hardwater Bypass Valve [V3070FM], Clack® Vertical 90 Degree Adaptor Kit [V3191-01]
All WS1 CI Valves are equipped as standard with 2 off 12V Relay – contact OSMIO for advice for use
OSMIO advise to follow any local or national regulations regarding plumbing or electrical installation
SIMPLEX NITRATE UNITS, 75 – 250 LITRES
Simplex Units with Clack® WS1 Valves, Time Clock (TC) and Metered (CI)
Resin Volume | 75 litres | 100 litres | 150 litres | 200 litres | 250 litres |
PART No | WF1354TC-N | WF1465TC-N | WF1665TC-N | WF1865TC-N | WF2160TC-N |
Time Clock Valve price ex VAT | Call for price | Call for price | Call for price | £3,349.23 | Call for price |
PART No | WF1354CI-N | WF1465CI-N | WF1665CI-N | WF1865CI-N | WF2160CI-N |
Metered Valve price ex VAT | Call for price | Call for price | Call for price | Call for price | Call for price |
Tank Size (inches) | 13 x 54 | 14 x 65 | 16 x 65 | 18 x 65 | 21 x 60 |
Recommended Service Flow (m3/hr) | 3.0 | 4.0 | 6.0 | 6.0 | 6.0 |
Volume Capacity between Regens @ 75 ppm (m3) | 20.0 | 26.7 | 40.0 | 53.3 | 66.7 |
Brine Tank Volume (litres) | 140 | 140 | 190 | 340 | 460 |
Salt Usage per Regen (kgs) | 11.25 | 15.0 | 22.5 | 30.0 | 37.5 |
WS1 Injector Colour | Green | Orange | Light Blue | Light Green | Light Green |
WS1 Drain Line Flow Controller | 053 | 065 | 075 | 090 | 150 |
Approx Footprint DxWxH - cm | 58x90x157 | 58x96x185 | 58x100x188 | 74x120x188 | 85x140x175 |
Approx Regen Duration (minutes) | 80 | 95 | 85 | 95 | 90 |
NOTE:
Optional extras include – Clack® Valve Wrench [V3193], Clack® 1" Bypass Valve Assembly [V3006], Clack® ¾" Male BSP Adaptor Kit [V3007-14], Clack® No Hardwater Bypass Valve [V3070FM], Clack® Vertical 90 Degree Adaptor Kit [V3191-01]
All WS1 CI Valves are equipped as standard with 2 off 12V Relay – contact OSMIO for advice for use
OSMIO advise to follow any local or national regulations regarding plumbing or electrical installation